Register Descriptions
F-68 AT Commands
S12 Escape Code Guard Time and Remote Access Attention Sequence
Guard Time
Range:
0 - 255 (fiftieths of a second)
Default:
50 (1 second)
Sets the minimum “quiet” time that must be present before and after entering the three-
character escape code or the remote access attention sequence. The time delay between
each character in the escape code or remote access attention sequence must be less than
this guard time. If register S12 is set to 0, the time it takes to enter the escape code or
remote access attention sequence does not affect recognition.
NOTES
•
The modem does not store this register with &W; use *W to save it.
•
Register S12 sets the guard time that precedes and follows the attention character
sequence. For the remote access attention sequence guard time during normal
mode, S12 should be set to the same value on both the originating and answering
modems. Reliable mode uses its own timing and register S12 is ignored.