AT Commands F-67
Register Descriptions
S10 Delay for Hang Up After Carrier Loss
Range:
0 - 255 tenths of a second
Default:
60 (6 seconds)
Sets the length of time the modem waits before hanging up after loss of carrier,
allowing for a temporary loss. Both modems should have equal S10 values. Otherwise,
disconnect occurs when the lower value is reached. When register S10 is set to 255,
the modem functions as if carrier is always present.
After disconnecting, the modem waits for a minimum of five seconds before going off
hook again in originate mode.
NOTES
•
The modem does not store this register with &W; use *W to save it.
•
Register S10 is ignored during V.34, V.32bis, V.32, V.22bis, and V.22 reliable
connections.
S11 DTMF Tone Dialing Speed
Range:
50 - 100 milliseconds
Default:
75 milliseconds
Sets the length of time after the last tone was sent and before the next tone is sent when
the modem is dialing over a touch tone line.
NOTE
The modem does not store this register with &W; use *W to save it.