Removing and Replacing Field Replaceable Units
3.15 Removing the DSW42 Synchronous Communications Option
3. Remove the DSW42 input/output cable from the enclosure.
Figure 3–39 Removing the DSW42 Input/Output Cable
DSW42 Input/Output Module
DSW42 Input/Output Cable
CPU Module
MLO-009878
3.15.3 Removing the DSW42 Input/Output Module
To remove the DSW42 input/output module, follow these steps:
1. Disconnect the external cables that connect to synchronous ports 0 and 1
on the back of the system unit (if not already disconnected).
2. Disconnect the DSW42 input/output cable from the DSW42 input/output
module (if not already disconnected).
3. Press the spring clip on the DSW42 input/output module. Pull the DSW42
input/output module towards the front of the enclosure until it is released
from the back of the enclosure (refer to Figure 3–40).
3–62 Removing and Replacing Field Replaceable Units