![Digi IX20 Скачать руководство пользователя страница 655](http://html.mh-extra.com/html/digi/ix20/ix20_user-manual_2496666655.webp)
Diagnostics
Analyze network traffic
IX20 User Guide
655
(config network analyzer
name
)> schedule enable true
(config network analyzer
name
)>
b. Set the mode that will be used to run the capture filter:
(config network analyzer
name
)> when
mode
(config network analyzer
name
)>
where
mode
is one of the following:
n
boot
: The script will run once each time the device boots.
n
interval
: The script will start running at the specified interval, within 30 seconds
after the configuration change is saved. If
interval
is selected, set the interval:
(config add network analyzer
name
)> on_interval
value
(config add network analyzer
name
)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes
the format
number
{
w|d|h|m|s
}.
For example, to set
on_interval
to ten minutes, enter either
10m
or
600s
:
(config network analyzer name)> on_interval
600s
(config network analyzer name)>
n
set_time
: Runs the script at a specified time of the day. If
set_time
is set, set the
time that the script should run, using the format
HH
:
MM
:
(config network analyzer
name
)> run_time
HH
:
MM
(config network analyzer
name
)>
n
maintenance_time
: The script will run during the system maintenance time
window.
c. Set the amount of time that the scheduled analyzer session will run:
(config network analyzer
name
)> duration
value
(config network analyzer
name
)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes the
format
number
{
w|d|h|m|s
}.
For example, to set
duration
to ten minutes, enter either
10m
or
600s
:
(config network analyzer name)> save_interval 600s
(config network analyzer name)>
d. Set the frequency with which captured events will be saved:
(config network analyzer
name
)> save_interval
value
(config network analyzer
name
)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes the
format
number
{
w|d|h|m|s
}.
For example, to set
save_interval
to ten minutes, enter either
10m
or
600s
:
Содержание IX20
Страница 1: ...IX20 User Guide ...
Страница 598: ...Monitoring This chapter contains the following topics intelliFlow 599 Configure NetFlow Probe 606 IX20 User Guide 598 ...
Страница 613: ...Central management Configure Digi Remote Manager IX20 User Guide 613 ...
Страница 640: ...Diagnostics View system event logs IX20 User Guide 640 5 Click to download the system log ...
Страница 707: ...Command line interface Command line reference IX20 User Guide 707 more path The file to view Syntax STRING ...
Страница 710: ...Command line interface Command line reference IX20 User Guide 710 reboot Reboot the system Parameters None ...