29
DHOLLANDIA
11.3
INSTALLATION OF EXTRA CONTROLS
–
2 BUTTON REMOTE CONTROL (OAE001
–
E0787.2.H)
•
Mount the 2-button remote in a position that allows the operator to
work from a safe standing area at the side of the liftgate,
outside reach of the platform and other moving parts of the lift
.
•
Mount it in a location that is accessible from the ground and the vehicle floor level.
NOTICE
•
In order to avoid water ingress and mechanical malfunction, NEVER mount the receptacle plug
vertically
.
•
Mount the 2-button remote in a position that allows the
operator
to work from a safe standing area
.
•
Position the control holster in a way that stows the remote
with the least amount of slack in the cable.
•
Measure the holes on the holster and receptacle units and
use them to drill the screw holes.
•
Use #10-32
–
1inch (4.3mm) self-tapping screws to mount the
control holster and receptacle.
•
Route the electrical cable to the pump unit. Position, fasten
and protect it in such a way that it cannot be damaged by the
moving parts of the liftgate or other vehicle components.
•
Feed the electrical cable through the rubber cover at the rear
of the pump unit.
Check and make sure the rubber cover
properly seals and protects the inside of the pump unit,
after passing the cable.
•
Prevent ingress of water into the pump unit and control boxes
if applicable.
•
Route and secure cables downward, forming a “drip loop” as
they exit the pump unit.
•
Connect the wires of the cable to the connection points in the
pump unit, as per wiring diagram below.