52
DHOLLANDIA
19.3
ELECTRIC AND HYDRAULIC REQUIREMENTS
•
The applicable wiring diagrams are saved at the inside of the main external control box and can be found there for reference.
•
A copy of the wiring diagrams can also be obtained from the national DHOLLANDIA distributor [see contact info on
page 4]; or downloaded from the DHOLLANDIA website:
www.dhollandia.com → Country & language selection → Downloads → Electrical & hydraulic wiring
diagrams
→ … select r
equired diagram
•
Remark: the following cable sections are recommended (+) battery cables and (-) ground cables.
•
Note: these are general data. Subject to agreement with our order department. Other configurations are possible.
Recommended cable sections for (+) battery cables and (-) ground cables
Size electric motor
Cable section
500 W
16 mm² - 5 AWG
12V
●
1200
–
2000 W
1100
–
3300 lbs
capacity / length ≤
33 ft
1100
–
3300 lbs capacity / length 33
–
60 ft
Capacity > 3300 lbs
Length > 60 ft
3 AWG
1 AWG
0 (1/0) AWG
0 (1/0) AWG
24V
●
1200
–
2000 W
1100
–
4400 lbs
/ length ≤
60 ft
Capacity > 4400 lbs
Length > 60 ft
3 AWG
1 AWG
1 AWG
24V
●
3000 W
Length < 60 ft
Length > 60 ft
1 AWG
0 (1/0) AWG
Long motor cycles > 25 sec (double deck, power down)
0 (1/0) AWG
•
Batteries and their charging system should be chosen to comply with the following minimum requirements:
Voltage System
12V
24V
Liftgate capacity
(lb / kg)
Electrical power
(Amp)
Battery
capacity
(Ah)
Generator
output
(A)
Electrical
power
(Amp)
Battery
capacity
(Ah)
Generator
output
(A)
≤ 1750 lbs / 750 kg
200
143
70
150
105 (2X)
70
≤ 2200 lbs / 1000 kg
250
143
70
200
105 (2X)
70
≤ 3300 lbs / 1500 kg
250
180
90
200
180 (2X)
90
> 3300 lbs / 1500 kg
250
180
110
250
180 (2X)
110
> 3300 lbs / 1500 kg
Frequent usage
300
220
110
300
220 (2X)
110