![Dhollandia DH-RPH 33 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/dhollandia/dh-rph-33/dh-rph-33_installation-manual_2492157054.webp)
53
DHOLLANDIA
NOTICE
•
To ensure the reliability of the liftgate over many years, it is extremely important that the batteries, their charging system, the (+)
battery and (-) ground cables, fuses and circuit breakers are dimensioned sufficiently strong, and fitted with care following
DHOLLANDIA installation instructions. Insufficient battery power will cause harm and irreparable damage to the electric
components of the liftgate (starter solenoid, electric motor, electric switches, etc...).
•
Insufficient cable gauge on the (+) battery and (-) ground cables can lead to overheating, bad performance of the electrical
system, and premature wear of the main electrical components.
•
(-) Ground circuits are as important as (+) battery circuits for the good operation of the liftgate, but often overlooked in
troubleshooting. Make sure you take these into consideration when executing repairs or maintenance checks.
•
DHOLLANDIA mainly uses 3 types of oils in its hydraulic systems.
Option code
Temperature range
Type of oil, examples
Standard
Mild to hot
ISO VG 22
OAH001 winter oil
Down to -30°C / -22°F
ISO VG 15
OAH002 arctic oil
Down to -50°C / - 58°F
Hydr. Fluids such as Castrol Aero
HF585B
NOTICE
•
It is important to follow these guidelines with due care. A lot of oils or fluids used in automotive industry, such as transmission
fluids and ATF oils, are not suitable for liftgate use. DHOLLANDIA has not tested the potential consequences of oils and fluids
with deviating specifications and cannot be held responsible or legally liable for any damage to the liftgate caused by the
replenishment with non-compatible oils or fluids; nor for the consequential damage to property or physical harm to individuals.