Operation via TERM 24
Deutschmann Automation GmbH & Co. KG
76
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
As already described above, the address
of the connected cam control
on the DICNET
bus
can be changed by entering the new number.
The value is accepted if you confirm with
.
14.5.4
Defining the encoder type
Pressing the same key again or pressing
moves you to the next menu item. You will see
the following display:
X00 L48 PA000
Typ of Enc: 1
As already described above, the encoder type can be changed by entering the new number.
Please refer to the parameter description provided with the connected unit for the values permit-
ted.
The value is accepted when you confirm with
.
Pressing
quits the menu.
14.6 Logic functions
16 external hardware outputs of the cam control ('Axx' on the display) and 16 internal outputs
(markers; 'M' on the display) can be programmed and assigned a switch-off delay time if neces-
sary (outputs 1..8). Each output and marker may consist of a maximum of any three logic opera-
tions (AND, OR, NAND, NOR) and 4 operands. The following operands for the logic functions
can be used:
•
The 16 external hardware inputs (E01..E16)
•
The 16 internal cam outputs (N01..N16)
•
The 16 internal markers (M01..M16)
•
A 32-bit shift register
The outputs and markers may be inverted. They are displayed on the liquid-crystal display (LCD)
by the lower-case letters 'a' or 'm'.
In the state of delivery (no logic programmed), the external outputs are gated with the related
internal cam outputs, i. e. the cam control behaves as if no logic were present.
When you call this menu item, you will see the following display on the LCD (if no logic has yet
been programmed):