Operation via TERM 24
Deutschmann Automation GmbH & Co. KG
70
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
three values can be set output-by-output:
- Switching in both directions
- Switching only in positive direction
- Switching only in negative direction
On units with this option, you will see the symbol for the switching direction in the bottom line on
the display instead of the axis number.
The cursor can be positioned to the symbol with key
or
. You can choose the required
setting with keys
and save it with
.
Symbol
Meaning
Switching in both rotational directions
Switching in negative rotational direction
Switching in positive rotational direction
Only one direction can be defined per output. Once defined, this applies to
all programs.
However, outputs can be switched in parallel (wired-OR)!
14.3.13 Entering angle-time-cam
In case a LOCON 24, 48 or 64 features the option W, the first outputs are intended for entering
angle-time-cams.
On these outputs as many cams as desired can be entered as angle-/angle or as angle-time-
cams.
The switch-on point is programmed just like angle/angle-cams.
In case the cursor is set on the switch-off point, with the key
you can switch between the
angle/angle-cam and the angle/time-cam. The symbol switches from ’Switch-off point’ to ’ms’.
The switch-off time is entered in milliseconds. Values from 1 to 32500 are permissible.
14.3.14 Entering positions for the option analog outputs
If the LOCON 24 / LOCON 48 features the option analog outputs, 2 analog outputs are available.
In this case LOCON 48 only has 40 regular outputs available.