24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
87
Deutschmann Automation GmbH & Co. KG
Basic device TERM 6 (external operating unit)
Should the adjusted value be dismissed and the old ID be restored, this takes place with the key
. In case there is no control system with the chosen ID in DICNET, it appears the display
"
- - - - -
"
If the TERM 6 features the RS232-interface (option), the 1. place shows the actual program, of
the connected cam control.
15.6 Display of the executed program via TERM 6
When connecting a LOCON with the operating and display unit TERM 6 via the RS232-interface,
the first place on the left side permanently displays the program that is executed that moment.
This only applies to a RS232-TERM 6, as the DICNET-version displays the device number at this
place.
15.7 Reading and changing cam control parameters
All cam control parameters that can be reached via the communication profile with GET/SET-
PARAMETER can be read and changed via a “menu point“ that is integrated in TERM 6.
Starting from the main menu the keys
and
are pressed for the same time period.
Thereupon the function LED shines and a 1 (current parameter number) appears on the display.
Now this number can be changed with
and
.
If, for instance, the encoder resolution is to be read / changed, please select (see parameter
table in the manual communication profile) the number 17 (corresponds to 11H =
PNR_RESOLUTION_PER_TURN). Confirm with
and the encoder resolution of the con-
nected cam control is displayed (e. g. 1000). If you want to change this value, please press
again (long) and then the Prog-LED starts to flash. Now the value can be changed with
or
. Then by pressing
the new value is loaded into the cam control, the value is rejected
with
. An error message appears if the cam control does not allow a change of this parame-
ter. An error message also appears (Error 36), if a not existing parameter is supposed to be read.
Special parameters in X-options can also be handled as described in this chapter.
15.8 Programming angle-time-cams via TERM 6
From the firmware T6V1-32.HEX of TERM 6 on, it is also possible to program angle-time-cams.
The angle-time-cams are presented by the LED „Function“, which shines in addition to the LED
„Off“ when the switch-off time is presented. When a switch-off point is presented, only the LED
„Off“ is shining.
The switch-over between these two modes takes place when the switch-off point/time is pro-
grammed with the key
.
This is only possible when a cam is reprogrammed and no switch-off value has been entered
then.
Angle-time cams can be deleted by entering 0 as switch-on time.
In case a switch-over is tried with a device that does not support angle-time-cams, the error 37 is
displayed.