LOCON LTC (special version)
Deutschmann Automation GmbH & Co. KG
38
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
8.2.2
Terminal allocation
Terminal allocation
Connection terminal
Designation
X1
0 - 1
Output no. 1 (cam)
0 - 2
... The outputs 1 to 8 are delayed cams and / or N-cycles.
...
... The outputs 1 to 8 are classical cams.
...
...
0 - 31
Output no. 31 (cam)
0 - 32
Output emergency power-off
0 - 33
Output to display the control cam of signal no. 1
...
... (Wiring of the requirement outputs)
0 - 48
Output to display the control cam of signal no. 16
X2
I01
Input signal no. 1
I02
Input signal no. 2
...
... These inputs allow to connect the sensors PNP 24V to the device.
I16
Input signal no. 16
X3
nc
Option SSI
X4
+24V
Power 24V of the encoder (in general: color red)
GND
Power supply 0V of the encoder (color: black)
ENC-1
Input bit 0 of the encoder (color: white)
ENC-2
Input bit 1 of the encoder (color: brown)
ENC-3
Input bit 2 of the encoder (color: green)
ENC-4
Input bit 3 of the encoder (color: yellow)
ENC-5
Input bit 4 of the encoder (color: grey)
ENC-6
Input bit 5 of the encoder (color: pink)
ENC-7
Input bit 6 of the encoder (color: purple)
ENC-8
Input bit 7 of the encoder (color: grey/pink)
ENC-9
Input bit 8 of the encoder (color: blue)
ENC-10
Not connected to encoder 360 pts gray excess
...
... Not connected to encoder 360 pts gray excess
ENC-13
Not connected to encoder 360 pts gray excess
+24V
Output 24V - allows the following connections.
PRGEnab
Input unblocking programming (+24V=unblocking)
PRGStart
Input validation of the program no., provided by the following terminals.
(Optional use if the keyboard is used for program change.)
PRG-01
These 4 inputs provide a number of the binary program (up to 16).
The program has to be activated by the input so that it will be active.
PRG-02
PRG-04
PRG-08
PRG-16
Input control-startup (+24V = in operation).
PRG-32
Input outer "rearment" (pulse +24V)
X5
+24V
Device's power supply input +24V
GND
Device's power supply input 0V
DIC-/RX
Communication input RS232 OR RS485 (DICNET) requirement wiring
DIC+/TX
Communication input RS232 OR RS485 (DICNET) requirement wiring
GND
Ground reference for communication RS232 requirement wiring
R-
Terminal resistance for RS485 requirement wiring
R+
Terminal resistance for RS485 requirement wiring
X6
ON
Contact "ON" differential relay (intensity max. 1A)
COM
Jointly differential relay (intensity max. 1A)
OFF
Contact "OFF" differential relay (intensity max. 1A)