LOCON LTC (special version)
Deutschmann Automation GmbH & Co. KG
44
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
LOCON 24 LTC is controlled within the cam if the input signal only changes the state in the
defined zones through the cam bosses.
The first cam boss determines the first change of state of the input signal and the second cam
then determines the second change of state of the input signal.
Example: If the input signal is at 0V at the beginning of the first cam boss, then the signal at 24V
has to be at the end of the first bosses. The second boss is supposed to show the opposite tran-
sition so that the control functions properly.
For each state of change of the sensor a detection boss has to be available.
This control type is outstandingly suitable for long signals in order to check the state of the sen-
sor between the two bosses.
8.5.4
Correspondence table
Signal-no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Input terminal of
the signal
I01
I02
I03
I04
I05
I06
I07
I08
I09
I10
I11
I12
I13
I14
I15
I16
Control cam in
correspondence
with the pro-
gramming
S33 S34 S35 S36 S37 S38 S39 S40 S41 S42 S43 S44 S45 S46 S47 S48
8.5.5
Description of the control error
The errors are displayed on the screen in 7 red segments. You use the number of the ERROR by
continuingly identifying the error which is produced on the way to the input.
No. of the input signalI01 = 1
No. of the input signalI02 = 2
No. of the input signalI X = X
Errors that are displayed by LOCON 24 LTC:
ERROR 140+X: