01/2018
52 / 80
6159933780
Issue no: 09
CVIL II
9 - CONNECTIONS
9.1 - PC wiring diagram
● number 6159170470
1
2
3
4
5
1 - DCD
2 - RD
3 - TD
4 - DTR
5 - GND
6 - DSR
7 - RTS
8 - CTS
1 - DCD
2 - RD
3 - TD
4 - DTR
5 - GND
6 - DSR
7 - RTS
8 - CTS
6
7
8
9
1
2
3
4
5
6
7
8
9
(a)
(a)
(b)
(b)
(c)
(c)
(d)
(d)
(e)
(e)
A
B
Legend
A Sub D 9 contacts socket (PC side)
B Sub D 9 contacts socket (Controller side)
a White
b Brown
c Blue
d Red
e Black
9.2 - S
ynchronizing several CVIL controllers
To synchronize several CVIL controllers, you must:
● Allocate the "Synchro In" and the "Synchro Out"
signals to unused inputs and outputs.
● Connect the controller Synchro signals and program
a "Synchr. Waiting Phase" for each controller.
The 0 VE of the I/O connectors of each
controller are connected to each other. All
other signals (cycle number, run...) must be
connected to each controller.
9.2.1 - Example of connection diagram
It is necessary to wire a diode 1N4148 in serial
with each synchro out signal.
Synchro
IN
Synchro
OUT
GND
Output
Input
1N4148
Controller 1
+24V
0VE
1
2
3
4
Stop 2
6
7
8
Stop 1
n.c.
GND
+24V
0VE
2
3
4
5
6
7
8
COM2
1
COM1
Synchro
IN
Synchro
OUT
GND
Output
Input
1N4148
Controller 2
+24V
0VE
1
2
3
4
Stop 2
6
7
8
Stop 1
n.c.
GND
+24V
0VE
2
3
4
5
6
7
8
COM2
1
COM1
Synchro
IN
Synchro
OUT
GND
Output
Input
1N4148
Controller 3
+24V
0VE
1
2
3
4
Stop 2
6
7
8
Stop 1
n.c.
GND
+24V
0VE
2
3
4
5
6
7
8
COM2
1
COM1
Содержание CVIL II
Страница 2: ......
Страница 12: ...01 2018 12 80 6159933780 Issue no 09 CVIL II 4 2 2 Language selection 4 2 3 Setting the date and time...
Страница 77: ...01 2018 77 80 6159933780 Issue no 09 CVIL II...
Страница 78: ...01 2018 78 80 6159933780 Issue no 09 CVIL II...
Страница 79: ...01 2018 79 80 6159933780 Issue no 09 CVIL II...
Страница 80: ...www desouttertools com More Than Productivity Copyright 2016...