01/2018
37 / 80
6159933780
Issue no: 09
CVIL II
7.7.4.1 - CVIL output, PLC input wiring
Below are shown the two wiring configurations available
for the relayed outputs of the CVIL.
● The PLC 24V is connected to the CVIL output
common. The PLC input do not receive external 24V.
+24V
0V
1
3
2
Legend
1 Controller output
2 PLC input
3 Common of the output relays
● By default, the PLC 24V is sent to the inputs of the
controller.
+24V
0V
0VE
1
3
2
Legend
1 Controller output
2 PLC input
3 Common of the output relays
All outputs are enabled at 1 and relayed in the controller
with a common point (4) for all outputs.
Features of the contacts: 1A / 30V / 30W max. DC on
resistive charge.