01/2018
42 / 80
6159933780
Issue no: 09
CVIL II
7.8.9 - CVINET menu
The CVINET software can be used to recover the
tightening results and the curves on PC via Ethernet.
This screen is the configuration of the CVINET data
collector.
Parameter
Comment
FIFO blocking
When the result memory to be
transmitted is full, the start cycle that
follows can be locked or not (the start
cycle is not locked on, but next results
are not saved).
Alarm thresh.
When the memory filling rate reaches
this value (1 to 99%), an alarm is
displayed.
Date synchro
Choose how to update the machine on
time (CVIPC / CVINET / CVIPC and
CVINET).
Results
Tightening results.
OK curves
Tightening curves with tightening
report=accept.
NOK curves
Tightening curves with tightening
report=reject.
FIFO capacity
Memory space allocated for not
transmitted results.
FIFO used
Memory space used in the FIFO.
Connection
status
NOK: not connected to the CVINET
server.
OK: connection established.