7.7.5 - RUN REVERSE menu
Parameters
Comments
Tool En. Rev.
● Yes: the operator cannot
perform a loosening operation
unless the SPVALRV (spindle
reverse validation) input is
activated.
● No: the operator is allowed to
perform a loosening operation.
Rev
Type
Default
Reverse in opposite of the spindle
way with default parameters.
LastPha
Reverse in the opposite way of the
last tightening phase programmed
in the current cycle.
OnCycle
Use a cycle programmed in the
cycles list.
The next display depends on the Reverse type
(Rev Type)
Rv speed
Speed for the continuous reverse.
Rev Cyc N
List of valid cycles programmed in
the cycles list. ("none" if no cycle
programmed).
7.8 - PERIPHERALS menu
7.8.1 - SERIAL PORT menu
The serial port is used for the following functions:
● PC transfer (used to communicate with CVIPC 2000
software).
● Bar code and report output.
● Printing the results in order of occurrence (ASCII, use
Bar code and report output selection).
● Automatic calibration with the DELTA measuring unit
(no programming is required).