![Deprag AST40-1 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/deprag/ast40-1/ast40-1_operating-instruction-booklet_2485170031.webp)
31
7.6.1.3.5 Description of the data structure of the screwdriving data (UDT23)
Designation
Data type Description
fd_Prog INT
Program number
The program number of the screwdriver program started
previously is output here.
fd_Status INT
Screw status
The screwdriver status is output here in detail.
(for possible status values, see
15.2 Error in the Screwdriving
fd_Time REAL
Screw fixing time
The screw fixing time (in seconds) necessary of the program
started previously is output here.
fd_Step1 DINT
(1)
The step number for the AST40 – program in which a data
backup (1) occurred is output here
fd_minTorque1 REAL
Lower torque limit of
The set lower torque limit of the data backup (1) is output
here.
fd_tarTorque1 REAL
(1)
The set lower torque setpoint of the data backup (1) is output
here.
fd_maxTorque1 REAL
(1)
The set upper torque limit of the data backup (1) is output
here.
(1)
The torque value of the data backup (1) is output here
fd_minAngle1 DINT
Lower angle of rotation limit of the
The set lower limit of the angle of rotation of the data backup
(1) is output here.
fd_tarAngle1 DINT
Angle of rotation setpoint of the
The set angle of rotation setpoint of the data backup (1) is
output here.
fd_maxAngle1 DINT
Upper limit of angle of rotation of the
The set upper limit of the angle of rotation of the data backup
(1) is output here.
fd_Angle1 DINT
Angle of rotation value of the
The angle value of the data backup (1) is output here
fd_Step2 DINT
(2)
The step number for the AST40 – program in which a data
backup (2) occurred is output here
fd_minTorque2 REAL
Lower torque limit of
The set lower limit of the angle of rotation of the data backup
(2) is output here.
fd_tarTorque2 REAL
The set lower torque setpoint of the data backup (2) is output
here.
fd_maxTorque2 REAL
Upper torque limit of the
The set upper torque limit of the data backup (2) is output
here