![Deprag AST40-1 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/deprag/ast40-1/ast40-1_operating-instruction-booklet_2485170016.webp)
16
6.2.7.3 Interface SPS 2
Designation:
GX3
Plug connector:
SUB-D 25-pole (bushing)
Pin Designation
Type
Pin Designation
Type
1 24V
-
14 GND
internal
-
2 24V
external
-
15 GND
external
-
3 Not in use
Input
16 n.c.
4 Sequence
5
Input
17 n.c.
5 Sequence
6
Input
18 Sequence
9
Input
6 Sequence
7
Input
19 Sequence
10
Input
7 Sequence
8
Input
20 Sequence
11
Input
8 Sequence
5
Output 21 Sequence
12
Input
9 Sequence
6
Output 22 Sequence
9
Output
10 Sequence
7
Output
23 Sequence
10
Output
11 Sequence
8
Output
24 Sequence
11
Output
12 n.c.
25 Sequence
12
Output
13 n.c.
Table 6:
Configuration I/O interface SPS2
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
6.2.7.4 Interface
3
Designation:
GX4
Plug connector:
SUB-D 15-pole (bushing)
Pin Designation
Type
Pin Designation
Type
1 Not in use
Input
9 Not in use
Input
2 24V
Out
-
10 GND
external
-
3 24V
Out
-
11 GND
external
-
4 24V
Out
-
12 GND
external
-
5 Not in use
Input
13 Not in use
Output
6 Not in use
Output
14 Reload
Output
7 n.c.
15 GND
external
-
8 24V
Out
-
Table 7:
Configuration I/O interface 3
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
IMPORTANT
24V Out: 24 V DC power supply for the supply of external sensors.