12.2 Commands
12.2.1 Waiting for input
Waits for an input
Switching to the next sequence step will occur when the input is high.
Parameters:
• Maximum waiting time
• input number
12.2.2 Setting the output
Sets an output.
Parameter:
• Output number
• Time monitoring: yes / no
If time monitoring is switched on or enabled, the following parameter is also required:
◦
Time until reset
12.2.3 Resetting the output
Resets an output.
Parameter:
• Output number
12.2.4 Display values
Displays the values of the previous screwdriving level at the touch display. The command
can be used as often as you like.
12.2.5 Save values
Protects the values of the preceding screwdriving stage in the end value data set. The
command can be used as often as you like. The end value data can be loaded by means
of the web-based user interface from the AST40 sequence controller (also see
).
IMPORTANT
A maximum of the last three results are saved.
Results of NOK screwdriving is always saved.
12.2.6 Statistics
Has an effect on the calculation of the statistics of the preceding screwdriving stage (also
see
).
IMPORTANT
The statistic can only be calculated for a screwdriving level per program.
If the 'statistic' command is entered more than once into the program then
only the statistic for the last screwdriving level is calculated, for which the
'statistic' command has been indicated.
12.2.7 Waiting time
Inserts a waiting time into the program.
Parameter:
• Waiting time