Clone Status: unsupported
This means that Clone Block/Full Copy/Xcopy is
not supported.
Zero Status: supported
This means that write same is supported.
Delete Status: supported
This means that UNMAP is supported.
Note:
Thin provisioning is not shown in VAAI output.
Cache
VxFlex OS offers a number of caching options, for the purpose of enhancing system
performance.
The following caching options are supported by VxFlex OS:
l
RAM Read Cache (using DRAM server memory)
l
Read Flash Cache (using SSD and NVMe SSD devices)
In addition, the following caching solution is available, in VxFlex Ready Node systems
only:
l
DAS Cache (using SSD devices)
Note:
For the most updated list, see the DAS Cache support matrix at
topics-cdn.dell.com/pdf/dell-sandisk-das-cache_Reference-Guide_en-us.pdf
SSDs used for caching cannot be used for storage purposes.
Note:
If CacheCade or DAS Cache is used, you must configure External
acceleration. Some devices are already benefitting from an external (For example,
a non-VxFlex OS related) acceleration/caching mechanism. This input is required
in order to avoid alerts about media type mismatches. For example, when the user
adds an HDD device which the SDS perceives as being too fast to fit the HDD
criteria.
Read Flash Cache (RFcache) and DAS Cache cannot be used simultaneously in the
same Storage Pool. However, a node can contain devices using different caching
types, as long as the corresponding devices are allocated to different dedicated
Storage Pools (one Storage Pool using DAS Cache, and another using Read Flash
Cache.
The following table summarizes information about the caching modes provided by the
system.
Table 3 Caching modes
Mode
Description
Considerations
Default Setting
RAM Read Cache
(RMcache)
Read-only caching
performed by server
RAM.
RAM Read cache, the fastest type of caching,
uses RAM that is allocated for caching. Its size is
limited to the amount of allocated RAM.
Note:
The amount that may be allocated is limited,
and can never be the maximum available
RAM.
Disabled, except when
storage-only nodes are
deployed.
Read Flash Cache
(RFcache)
Read-only caching
performed by one or
more dedicated SSD or
RFcache uses the full capacity of SSD devices
(up to eight) to provide a larger footprint of
read-only LRU (Least Recently Used) based-
Architecture
38
Dell EMC VxFlex Ready Node AMS User Guide
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...