Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity
Recommended Action
Failure recovery
capacity is below the
threshold
FAILURE_RECOVERY_
CAPACITY_BELOW_TH
RESHOLD
MDM.Storage_
Pool.Failure_Re
covery_Capacit
y_Below_Thres
hold
SIO02.04.000
0005
3 (Error)
The capacity available for
recovery in a degraded
storage event is lower than
the predefined threshold.
Replace failed hardware or
add more physical storage.
Configured spare
capacity is smaller
than largest fault
unit
CONFIGURED_SPARE_
CAPACITY_SMALLER_T
HAN_LARGEST_FAULT
_UNIT
MDM.Storage_
Pool.Configure
d_Spare_Capac
ity_Smaller_Th
an_Largest_Fa
ult_Unit
SIO02.04.000
0008
2 (Warning)
Increase the "spare
percentage" configured in
the system for the Storage
Pool, so that the capacity
reserved for failure
recovery is larger than the
largest fault unit in the
Storage Pool.
The Storage Pool
relies too heavily
(over 50%) on
capacity from a
single SDS or Fault
Set. Balance
capacity over other
SDSs or Fault Sets.
STORAGE_POOL_UNB
ALANCED
MDM.Storage_
Pool.STORAGE
_POOL_UNBAL
ANCED
SIO02.04.000
0009
3 (Error)
Move some physical disks
from the large SDS to the
others, or add disks to the
smaller SDS in order to
approximate the capacity of
the large SDS as much as
possible.
Storage Pool does
not meet the
minimum
requirement of 3
fault units
NOT_ENOUGH_FAULT
_UNITS_IN_SP
MDM.Storage_
Pool.Not_Enou
gh_Fault_Units
SIO02.04.000
0010
3 (Error)
Add more SDSs to the
Storage Pool to meet the
minimum requirement of 3
hosts.
In the Storage Pool,
some devices are
not being cached
(using DAS Cache),
even though the
Storage Pool is
marked as cached
CACHECADE_NOT_US
ED_IN_STORAGE_POO
L_THOUGH_IT_SHOUL
D
MDM.Storage_
Pool.Das_Cach
e_Not_Used_In
_Storage_Pool
_Though_It_Sh
ould
SIO02.04.000
0013
2 (Warning)
Check the caching
configuration of those
devices. Caching needs to
be enabled at both device
and Storage Pool levels.
In the Storage Pool,
some devices are
being cached (using
DAS Cache) even
though the Storage
Pool is not marked
as cached
CACHECADE_USED_IN
_STORAGE_POOL_TH
OUGH_IT_SHOULDNT
MDM.Storage_
Pool.Das_Cach
e_Used_In_Sto
rage_Pool_Tho
ugh_It_Shouldn
t
SIO02.04.000
0014
2 (Warning)
Stop DAS Cache on the
Storage Pool.
There are cluster
certificates pending
approval. For more
information, open
UNTRUSTED_CERTIFIC
ATE
MDM.CERTIFIC
ATE.UNTRUST
ED_CERTIFICA
TE
SIO02.05.00
00001
3 (Error)
Pending for approval
certificates can be viewed
and approved via System
Settings > Connection.
SNMP Trap Support
Dell EMC VxFlex Ready Node AMS User Guide
299
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...