a. From the VxFlex OS CLI (SCLI), run:
scli --query_cluster
Note:
The SCLI is installed as part of the MDM component and can be
found in the following path:
l
ESXi (SVM) —
scli
l
Linux —
scli
b. If the node's IP addresses are included in the
--query_cluster
output,
the faulty node has a role of either MDM or TieBreaker (TB), in addition to
its SDS role.
If the node's IP address is located in the Master MDM role, a switch-over
action is required.
c. Switch MDM ownership to a different node:
scli -switch_mdm_ownership (-new_master_mdm_id
<ID>
| --
new_master_mdm_ip
<IP>
| --new_master_mdm_name
<NAME>
)
The node remains in the cluster. The cluster will be in degraded mode after it
is powered off, until the faulty component or patch operation in the node is
fixed and the node is powered back on.
d. Verify that the cluster status shows that the node is not the Master MDM
anymore:
scli --query_cluster
Output similar to the following should appear, with the relevant node
configuration and IP addresses for your deployment:
Cluster:
Mode: 5_node, State: Normal, Active: 5/5, Replicas: 3/3
Virtual IP Addresses: 9.20.10.100, 9.20.110.100
Master MDM:
ID: 0x775afb2a65ef1f02
IP Addresses: 9.20.10.104, 9.20.110.104, Management
IP Addresses: 10.136.215.239, Port: 9011, Virtual IP
interfaces: sio_d_1, sio_d_2
Version: 2.0.13000
Slave MDMs:
ID: 0x5b2e9f273b7af9b0
IP Addresses: 9.20.10.105, 9.20.110.105, Management
IP Addresses: 10.136.215.223, Port: 9011, Virtual IP
interfaces: sio_d_1, sio_d_2
Status: Normal, Version: 2.0.13000
ID: 0x5828f65b15e778f1
IP Addresses: 9.20.10.102, 9.20.110.102, Management
IP Addresses: 10.136.215.232, Port: 9011, Virtual IP
interfaces: sio_d_1, sio_d_2
Status: Normal, Version: 2.0.13000
Tie-Breakers:
ID: 0x6618e0b804644ca4
IP Addresses: 9.20.10.101, 9.20.110.101, Port: 9011
Status: Normal, Version: 2.0.13000
Common Tasks
Dell EMC VxFlex Ready Node AMS User Guide
271
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...