Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity
Recommended Action
modules (if needed), and
return to CLUSTERED
mode as soon as possible.
Inactive Protection
Domain
PD_INACTIVE
MDM.Protectio
n_Domain.Prot
ection_Inactive
SIO02.02.000
0001
2 (Warning)
Protection Domain was
inactivated by a user
command. Confirm that this
is an expected operation.
This is usually done for
maintenance. When
maintenance is complete,
reactivate the Protection
Domain.
Storage Pool has
failed capacity
STORAGE_POOL_HAS_
FAILED_CAPACITY
MDM.Storage_
Pool.Storage_P
ool_has_Failed
_Capacity
SIO02.04.000
0001
5 (Critical)
For the given Storage Pool,
for some blocks, both
primary and secondary
copies are inaccessible.
Check and fix the state of
all devices in the Storage
Pool and all the server's
holding devices in the
Storage Pool.
Storage Pool has
degraded capacity
STORAGE_POOL_HAS_
DEGRADED_CAPACITY
MDM.Storage_
Pool.Storage_P
ool_has_Degra
ded_Capacity
SIO02.04.000
0002
3 (Error)
For the given Storage Pool,
for some blocks, one of the
two copies is inaccessble.
Check if a server is offline
or if there is another server
hardware-related issue.
Check if a storage device is
down.
Capacity utilization
above critical
threshold
CAPACITY_UTILIZATIO
N_ABOVE_CRITICAL_T
HRESHOLD
MDM.Storage_
Pool.Capacity_
Utilization_Abo
ve_Critical_Thr
eshold
SIO02.04.000
0003
5 (Critical)
Due to thinly provisioned
volumes or snapshot usage,
the capacity utilization of
the Storage Pool is
reaching a critical
threshold. Remove
snapshots, if possible, or
add physical storage.
Capacity utilization
above high threshold
CAPACITY_UTILIZATIO
N_ABOVE_HIGH_THRE
SHOLD
MDM.Storage_
Pool.Capacity_
Utilization_Abo
ve_High_Thres
hold
SIO02.04.000
0004
2 (Warning)
3 (Error)
Due to thinly provisioned
volumes or snapshot usage,
the capacity utilization of
the Storage Pool is
reaching a high threshold.
Remove snapshots, if
possible, or add physical
storage.
SNMP Trap Support
298
Dell EMC VxFlex Ready Node AMS User Guide
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...