Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity
Recommended Action
time left and
limits
VxFlex OS is using a
trial license
TRIAL_LICENSE_USED
System.License
.Trial_License_
Used
SIO01.02.000
0003
2 (Warning)
Purchase a license and
install it.
Oscillating failures
reported
OBJECT_HAS_OSCILLA
TING_FAILURES
System.Oscillati
ng_Failures.Obj
ect_has_oscilla
ting_failures
SIO01.03.000
0001
2 (Warning)
Check oscillating failures of
the component and take
action accordingly. If the
oscillating failure does not
indicate a problem, change
the settings of the
oscillating failure window to
supress this alert
There are oscillating
network failures
OBJECT_HAS_OSCILLA
TING_NETWORK_FAIL
URES
System.Oscillati
ng_Failures.OB
JECT_HAS_OS
CILLATING_NE
TWORK_FAILU
RES
SIO01.03.000
0002
2 (Warning)
Check the oscillating failure
report, that can be
accessed from one of the
management interfaces.
Check whether there is a
problem with network links,
fix, and restart the
counters.
Invalid MDM
monitoring
credentials are
configured in the
AMS
AMS_CONFIGURATION
_INVALID_MDM_CRED
ENTIALS
System.Creden
tials.Ams_Confi
guration_Invalid
_Mdm_Credent
ials
SIO01.04.000
0003
5 (Critical)
Check the MDM credentials
configured in the AMS, and
modify them if necessary
The AMS cannot
connect to the MDM
cluster, but the
cluster itself is
operational
AMS_LOST_CONNECTI
ON_TO_MDM
System.MDM_
Cluster.Ams_Lo
st_Connection_
To_Mdm
SIO01.06.000
0001
5 (Critical)
Switch MDM ownership
using one of the
management interfaces.
This change may pass
cluster control to a master
MDM to which the AMS
can establish a connection.
The MDM is not
operating in
clustered mode
MDM_NOT_CLUSTERE
D
MDM.MDM_Cl
uster.MDM_No
t_Clustered
SIO02.01.000
0001
5 (Critical)
MDM cluster was manually
set to SINGLE mode.
Confirm that this is an
expected operation.
Working in SINGLE mode is
not recommended. Prepare
the cluster modules (if
needed), and return to
CLUSTER mode.
MDM fails over
frequently
MDM_FAILS_OVER_FR
EQUENTLY
MDM.MDM_Cl
uster.MDM_Fail
SIO02.01.000
0003
5 (Critical) 3
(Error) 2
(Warning)
The MDMs frequently swap
ownership. No action
required.
SNMP Trap Support
296
Dell EMC VxFlex Ready Node AMS User Guide
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...