device with a device containing less storage capacity, you can configure the device to
a smaller capacity than its actual capacity, in preparation for replacement. This will
reduce rebuilding and rebalancing operations in the system later on. For more
information, see
“Setting device capacity limits”
The system has job queues for operations that take a long time to execute. You can
view the jobs in the Backend Planned Rebuilds and Planned Rebalancing table
views.
There are two ways of removing devices from a system:
l
From the Hardware view—for details, see
“Using the Hardware view to remove
l
From the Backend view—for details, see
“Using the Backend view Remove
. This procedure can only be used to remove a device providing storage.
It cannot be used for a device providing caching.
Using the Hardware view to remove and replace a device
This topic explains how to remove a device using the Remove command in the
Hardware view.
NOTICE
The Remove command deletes the specified objects from the system. Use the
Remove command with caution.
In general, if you want to remove and replace a device, follow these steps:
1. Gather information about the faulty device and the SDS.
2. Remove the faulty device from the VxFlex OS system.
3. Remove the faulty, physical device from the server.
4. Add the replacement device to the server.
5. Add the replacement device to the VxFlex OS system.
6. Ensure that there are no errors.
Identifying a faulty device
About this task
The steps to perform are different, depending on whether the device is providing
caching (as in the case of some SSD disks), or whether it is used for storage (all HDD
disks and some SSD or NVMe SSD disks). Our first step is to locate the faulty device
in the VxFlex OS GUI, and then to determine its use.
Procedure
1. Identify the faulty disk:
a. Log in the VxFlex OS GUI, and from the Monitor > Alerts view, find the
node that has a faulty disk alert message.
b. From that node's Hardware view, write down the following:
l
Node information
l
Disk WWN
l
Disk slot number
c. From the Hardware view, locate the node and the faulty disk.
The faulty disk is colored orange.
Configuring the System using the VxFlex OS GUI
Dell EMC VxFlex Ready Node AMS User Guide
193
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...