Once the
trust
command has been issued on a disk group, further troubleshooting steps may be limited towards disaster recovery. If you
are unsure of the correct action to take, contact technical support for further assistance.
Events sent as indications to SMI-S clients
If the storage system’s SMI-S interface is enabled, the system will send events as indications to SMI-S clients so that SMI-S clients can
monitor system performance. For information about enabling the SMI-S interface, see the chapter about configuring the system in your
product’s Storage Management Guide.
The event categories below pertain to FRU assemblies and certain FRU components.
FRU/Event category Corresponding SMI-S class
Operation status values that would trigger alert conditions
Controller
DHS_Controller
Down, Not Installed, OK
Hard Disk Drive
DHS_DiskDrive
Unknown, Missing, Error, Degraded, OK
Fan
DHS_PSUFan
Error, Stopped, OK
Power Supply
DHS_PSU
Unknown, Error, Other, Stressed, Degraded, OK
Temperature Sensor
DHS_OverallTempSensor
Unknown, Error, Other, Non-Recoverable Error,
Degraded, OK
Battery/SuperCap
DHS_SuperCap
Unknown, Error, OK
FC Port
DHS_FCPort
Stopped, OK
SAS Port
DHS_SASTargetPort
Stopped, OK
iSCSI Port
DHS_ISCSIEthernetPort
Stopped, OK
140
Events and event messages
Содержание PowerVault ME484
Страница 1: ...Dell EMC ME4 Series Owner s Manual ...