Number
Severity
Description/Recommended actions
Recommended actions:
•
To continue using the feature, purchase a permanent license.
Info.
The temporary license for a feature will expire in 10 days. Any components created with the feature will remain
accessible but new components cannot be created.
Recommended actions:
•
To continue using the feature after the trial period, purchase a permanent license.
317
Error
A serious error has been detected on the Storage Controller's disk interface. The controller will be killed by its
partner.
Recommended actions:
•
Visually trace the cabling between the controller modules and expansion modules.
•
If the cabling is OK, replace the controller module that logged this event.
•
If the problem recurs, replace the expansion module that is connected to the controller module.
319
Warning
The indicated available disk has failed.
Recommended actions:
•
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the same or greater
capacity. For continued optimum I/O performance, the replacement disk should have performance that is
the same as or better than the one it is replacing.
322
Warning
The controller has an older Storage Controller (SC) version than the version used to create the CHAP
authentication database in the controller’s flash memory.
The CHAP database cannot be read or updated. However, new records can be added, which will replace the
existing database with a new database using the latest known version number.
Recommended actions:
•
Upgrade the controller firmware to a version whose SC is compatible with the indicated database version.
– If no records were added, the database becomes accessible and remains intact.
– If records were added, the database becomes accessible but contains only the new records.
352
Info.
Expander Controller (EC) assert data or stack-dump data are available.
Recommended actions:
•
No action is required.
353
Info.
Expander Controller (EC) assert data and stack-dump data have been cleared.
Recommended actions:
•
No action is required.
354
Warning
SAS topology has changed on a host port. At least one PHY has gone down. For example, the SAS cable
connecting a controller host port to a host has been disconnected.
Recommended actions:
•
Check the cable connection between the indicated port and the host.
•
Monitor the log to see if the problem persists.
Info.
SAS topology has changed on a host port. At least one PHY has become active. For example, the SAS cable
connecting a controller host port to a host has been connected.
110