3
Enter the
#set advanced-settings single-controller
CLI command.
Step 3 changes the redundancy settings to
Single Controller Mode
.
Enclosure management
The enclosure is mechanically and electrically compliant with the Storage Bridge Bay (SBB) v 2.1 specification. SBB IOMs actively manage
the enclosure. Each module has a SAS expander with its own storage enclosure processor (SEP) that provides a SES target for a host to
interface to through the ANSI SES Standard. If one of these modules fails, the other module continues to operate.
Management interfaces
Upon completing the hardware installation, you can access the controller module’s web-based management interface—ME Storage
Manager—to configure, monitor, and manage the storage system. The controller module also provides a CLI in support of command entry
and scripting. For details, see the
Dell EMC ME4 Series Storage System CLI Guide
for your system.
Operation
CAUTION:
Operation of the enclosure with any CRU modules missing will disrupt the airflow, and the enclosure will not receive
sufficient cooling. It is essential that all slots hold modules before the enclosure system is used. Empty drive slots (bays) in 2U
enclosures must hold blank drive carrier modules.
•
Read the module bay caution label affixed to the module being replaced.
•
Replace a defective power cooling module (PCM) with a fully operational PCM within 24 hours. Do not remove a defective PCM unless
you have a replacement model of the correct type ready for insertion.
•
Before removal/replacement of a PCM or power supply unit (PSU), disconnect power supply from the module to be replaced.
•
Read the hazardous voltage warning label affixed to power cooling modules.
CAUTION:
5U84 enclosures only
•
To prevent overturning, drawer interlocks stop users from opening both drawers at the same time. Do not attempt to force open a
drawer when the other drawer in the enclosure is already open. In a rack containing more than one 5U84 enclosure, do not open more
than one drawer per rack at a time.
•
Read the hot surface label affixed to the drawer. Operating temperatures inside enclosure drawers can reach 60ºC. Take care when
opening drawers and removing disk drives in carrier (DDICs).
•
Due to product acoustics, ear protection should be worn during prolonged exposure to the product in operation.
•
Open drawers must not be used to support any other objects or equipment.
NOTE:
for details about various 2U12 enclosure options.