Number
Severity
Description/Recommended actions
Recommended actions:
•
Take appropriate action based on the indicated problem.
Info.
The scheduler experienced a problem with the indicated task.
Recommended actions:
•
No action is required.
363
Error
When the Management Controller (MC) is restarted, firmware versions that are currently installed are
compared against those in the bundle that was most recently installed. When firmware is updated, it is
important that all components are successfully updated or the system may not work correctly. Components
checked include the CPLD, Expander Controller (EC), Storage Controller (SC), and MC.
Recommended actions:
•
Reinstall the firmware bundle.
Info.
When the Management Controller (MC) is restarted, firmware versions that are currently installed are
compared against those in the bundle that was most recently installed. If the versions match, this event is
logged as Informational severity. Components checked include the CPLD, Expander Controller (EC), Storage
Controller (SC), and MC.
Recommended actions:
•
No action is required.
364
Info.
The broadcast bus is running as generation 1.
Recommended actions:
•
No action is required.
365
Error
An uncorrectable ECC error occurred in Storage Controller CPU memory more than once, indicating a
probable hardware fault.
Recommended actions:
•
Replace the controller module that logged this event.
Warning
An uncorrectable ECC error occurred in Storage Controller CPU memory.
This event is logged with Warning severity to provide information that may be useful to technical support, but
no action is required now. It will be logged with Error severity if it is necessary to replace the controller module.
Recommended actions:
•
No action is required.
400
Info.
The indicated log has filled to a level at which it needs to be transferred to a log-collection system.
Recommended actions:
•
No action is required.
401
Warning
The indicated log has filled to a level at which diagnostic data will be lost if not transferred to a log-collection
system.
Recommended actions:
•
Transfer the log file to the log-collection system.
402
Error
The indicated log has wrapped and has started to overwrite its oldest diagnostic data.
112
Events and event messages
Содержание PowerVault ME484
Страница 1: ...Dell EMC ME4 Series Owner s Manual ...
Страница 64: ...3 4 5 64 Module removal and replacement ...