Number
Severity
Description/Recommended actions
Recommended actions:
•
Investigate why the log-collection system is not transferring the logs before they are overwritten. For
example, you might have enabled managed logs without configuring a destination to send logs to.
412
Warning
One disk in the indicated RAID-6 disk group failed. The disk group is online but has a status of FTDN (fault
tolerant with a down disk).
If a dedicated spare (linear only) or global spare of the proper type and size is present, that spare is used to
automatically reconstruct the disk group. Events 9 and 37 are logged to indicate this. If no usable spare disk is
present, but an available disk of the proper type and size is present and the dynamic spares feature is enabled,
that disk is used to automatically reconstruct the disk group and event 37 is logged.
Recommended actions:
•
If event 37 was not logged, a spare of the proper type and size was not available for reconstruction.
Replace the failed disk with one of the same type and the same or greater capacity and, if necessary,
designate it as a spare. Confirm this by checking that events 9 and 37 are logged.
•
Otherwise, reconstruction automatically started and event 37 was logged. Replace the failed disk and
configure the replacement as a dedicated spare (linear only) or global spare for future use.
•
For continued optimum I/O performance, the replacement disk should have the same or better
performance.
•
Confirm that all failed disks have been replaced and that there are sufficient spare disks configured for
future use.
442
Warning
Power-On Self Test (POST) diagnostics detected a hardware error in a UART chip.
Recommended actions:
•
Replace the controller module that logged this event.
443
Error
The firmware for the indicated enclosure is not supported in this configuration.
The firmware for the indicated enclosure does not support this enclosure for use as an expansion chassis. Its
firmware supports this enclosure only as a direct attached JBOD.
Recommended actions:
•
Replace the indicated enclosure. It is not supported.
454
Info.
A user changed the drive-spin-down delay for the indicated disk group to the indicated value.
Recommended actions:
•
No action is required.
455
Warning
The controller detected that the configured host-port link speed exceeded the capability of an FC SFP. The
speed has been automatically reduced to the maximum value supported by all hardware components in the
data path.
Recommended actions:
•
Replace the SFP in the indicated port with an SFP that supports a higher speed.
456
Warning
The system's IQN was generated from the default OUI because the controllers could not read the OUI from
the midplane FRU ID data during startup. If the IQN is wrong for the system's branding, iSCSI hosts might be
unable to access the system.
Recommended actions:
•
If event 270 with status code 0 is logged at approximately the same time, restart the Storage Controllers.
457
Info.
The indicated virtual pool was created.
Events and event messages
113
Содержание PowerVault ME484
Страница 1: ...Dell EMC ME4 Series Owner s Manual ...