Number
Severity
Description/Recommended actions
For non-fault-tolerant RAID levels (RAID 0 and non-RAID), media errors may indicate loss of data.
Recommended actions:
•
Resolve any non-disk hardware problems, such as a cooling problem or a faulty controller module,
expansion module, or power supply.
•
Check whether any disks in the disk group have logged SMART events or unrecoverable read errors.
– If so, and the disk group is a non-fault-tolerant RAID level (RAID 0 or non-RAID), copy the data to a
different disk group and replace the faulty disks.
– If so, and the disk group is a fault-tolerant RAID level, check the current state of the disk group. If it is
not FTOL then back up the data as data may be at risk. If it is FTOL then replace the indicated disk. If
more than one disk in the same disk group has logged a SMART event, back up the data and replace
each disk one at a time. In virtual storage it may be possible to remove the affected disk group, which
will drain its data to another disk group, and then re-add the disk group.
Warning
Disk group scrub did not complete because of an internally detected condition such as a failed disk. If a disk
fails, data may be at risk.
Recommended actions:
•
Resolve any non-disk hardware problems, such as a cooling problem or a faulty controller module,
expansion module, or power supply.
– If so, and the disk group is a non-fault-tolerant RAID level (RAID 0 or non-RAID), copy the data to a
different disk group and replace the faulty disks.
– If so, and the disk group is a fault-tolerant RAID level, check the current state of the disk group. If it is
not FTOL then back up the data as data may be at risk. If it is FTOL then replace the indicated disk. If
more than one disk in the same disk group has logged a SMART event, back up the data and replace
each disk one at a time. In virtual storage it may be possible to remove the affected disk group, which
will drain its data to another disk group, and then re-add the disk group.
Info.
Disk group scrub completed or was aborted by a user.
This event is logged as Informational severity when fewer than 100 parity or mirror mismatches are found and
corrected during a scrub.
For non-fault-tolerant RAID levels (RAID 0 and non-RAID), media errors may indicate loss of data.
Recommended actions:
•
No action is required.
208
Info.
A scrub-disk job has started for the indicated disk. The result will be logged with event 209.
Recommended actions:
•
No action is required.
209
Error
A scrub-disk job logged with event 208 has completed and found one or more media errors, SMART events,
or hard (non-media) errors. If this disk is used in a non-fault-tolerant disk group, data may have been lost.
Recommended actions:
•
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the same or greater
capacity. For continued optimum I/O performance, the replacement disk should have performance that is
the same as or better than the one it is replacing.
Warning
A scrub-disk job logged with event 208 has been aborted by a user, or has reassigned a disk block. These bad-
block replacements are reported as "other errors". If this disk is used in a non-fault-tolerant disk group, data
may have been lost.
Recommended actions:
•
Monitor the error trend and whether the number of errors approaches the total number of bad-block
replacements available.
Events and event messages