Number
Severity
Description/Recommended actions
CAUTION:
•
Avoid using the manual dequarantine operation as a recovery method when event 172 is logged
because this causes data recovery to be more difficult or impossible.
•
If you clear unwritten cache data while a disk group is quarantined or offline, that data will be
permanently lost.
Recommended actions:
•
If event 173 has subsequently been logged for the indicated disk group, no action is required. The disk
group has already been removed from quarantine.
•
Otherwise, perform the following actions:
– Check that all enclosures are powered on.
– Check that all disks and I/O modules in every enclosure are fully seated in their slots and that their
latches are locked.
– Reseat any disks in the quarantined disk group that are reported as missing or failed in the user
interface. (Do NOT remove and reinsert disks that are not members of the disk group that is
quarantined.)
– Check that the SAS expansion cables are connected between each enclosure in the storage system
and that they are fully seated. (Do NOT remove and reinsert the cables because this can cause
problems with additional disk groups.)
– Check that no disks have been removed from the system unintentionally.
– Check for other events that indicate faults in the system and follow the recommended actions for
those events. But, if the event indicates a failed disk and the recommended action is to replace the
disk, do NOT replace the disk at this time because it may be needed later for data recovery.
– If the disk group is still quarantined after performing the above steps, shut down both controllers and
then power down the entire storage system. Power it back up, beginning with any disk enclosures
(expansion enclosures), then the controller enclosure.
– If the disk group is still quarantined after performing the above steps, contact technical support.
595
Info.
This event reports the serial number of each controller module in this system.
Recommended actions:
•
No action is required.
598
Warning, Info. Drive has failed a performance measurement.
Recommended actions:
•
Monitor the disk.
599
Error
The firmware has yet to retrieve Enclosure Power control status.
The Enclosure Power element provides enclosure level power control. This could occur shortly after a reboot
or module insertion. It should only be treated as an error if it persists for more than 30 seconds after a reset.
Recommended actions:
•
Contact technical support.
•
When the problem is resolved, an event with the same code will be logged with Resolved severity.
Warning,
Resolved
The firmware has yet to retrieve Enclosure Power control status.
The Enclosure Power element provides enclosure level power control.
Recommended actions:
•
No action is required.
602
Error,
Warning
An alert condition was detected on a Midplane Interconnect element.