background image

OPERATIONS

MANUAL

 

i.Net 

Rack Mounted Headend Enclosure

 

(

Model G8350

)

 Document Number: 200-0008

 Re

v F

Содержание G8350

Страница 1: ...OPERATIONS MANUAL i Net Rack Mounted Headend Enclosure Model G8350 Document Number 200 0008 Rev F ...

Страница 2: ... Must Complete this process Table of Contents 1 2 In the event of trouble please contact Name Address Phone Number 21 22 23 4 7 10 13 14 18 WIRING General I O Configuring The System Using The System IP Settings Configuring the Time Settings Configuring the Fault Email Settings Configuring the SMTP Settings Troubleshooting Speaker Lines 24 14 20 19 ...

Страница 3: ...d from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury f...

Страница 4: ...ld only be changed by Authorized Personel The system is provided with a Communication Security Level 0 which indicates no Security Level employed The following wiring connections are intended to be protected against mechanical damage IN between G8350 and Fire Alarm Control Panel or Notification Appliance Circuits FAULT STATUS OUT between G8350 and Fire Alarm Control Panel or Notification Appliance...

Страница 5: ...all cover a minimum surface area equal to 8 of the overall side enclosure surface area Use UL2572 listed NAC Extenders driven by a N O dry contact and includes a N O dry contact fault output The UPS should be located in the same room as the equipment it is powering The UPS must be hardwired to the branch circuit and hardwired to the Rack Unit and any other Device if powered by the UPS The connecti...

Страница 6: ...gh building risers to create separate or additional zones The i Net Sound Masking Headend Rack unit allows the ability to use up to 255 individual zones for masking The system s easy to use full one third octave band equalizer can be adjusted to either individual zones or all zones and provides exceptional fine tuning capabilities The creation modification addition and deletion of zones for sound ...

Страница 7: ...allow the user to make a number of adjustments to the system without using a computer LCD display The front panel display is used for displaying a variety of information Protocessor The Protocessor is used to control the networked system The Protocessor offers exceptional features solid construction plus the flexibility to monitor and control the sound masking from virtually anywhere 2 ...

Страница 8: ...able to access the Protocessor not supervised 7 Aux Relays The Aux Relay R1 is used to send a fault to the FACP The other relays are for future use supervised by FACP 8 RS232 For future use 9 Inputs 1 4 Supervised Input 1 is used to mute the masking Connect the FACP mute output here supervised 10 Inputs 5 8 For future use supervised 11 Inputs 9 12 Input 11 UPS AC Fault Input 12 UPS Battery Fault I...

Страница 9: ...Wiring 4 ...

Страница 10: ...rear panel terminal block for the connection of an optional UPS The UPS output would connect to the terminal block 24VDC to pin 2 and 24V COM to pin 3 When a UPS is not used jumpers In to Out and In to Out must be installed Use a UL 864 listed power supply for the UPS The UPS must be 24VDC regulated until the power supply batteries are exhausted Lencore s PSM7A meets these requirements Incorporate...

Страница 11: ...n See the installation and operations manual for the i Net Rack OP for further wiring of OPs 2 Wire a ground wire from the headend GND to the first OP TO FIRST OP DATA IN TO FIRST OP Fire Alarm Connections 1 Connect the fire alarm panel normally open dry contacts Mute Masking inputs 6 ...

Страница 12: ...Relay Connection 1 Connect the FACP fault input to Aux Relay R1 NC and C Relay R1 is energized open when no fault exists and de energized closed when a fault is active To FACP Fault Input 7 ...

Страница 13: ...rent Option within that function The lower left displays the Channel or Zone that is related to the function The lower right displays the value associated with that channel or zone The FUNCTION button selects the function to be changed The OPT button selects the operation The up and down arrows increment and decrement the settings The SEL key is used to select operations To use the keypad first ch...

Страница 14: ...arrows to increment and decrement the selected value Zone Press the OPT button until ZN is displayed Press the SEL button until the curser is on the value to change Zone number or volume Use the up and down arrows to increment and decrement the selected value Masking Contour Press the FUNC button until Mask Cntr is displayed OP Channel Press the OPT button until OP is displayed Press the SEL butto...

Страница 15: ...o scroll through the fault list If the curser is on Clear or Mute the up or down arrow will clear or mute the fault The OPT button has no use for Faults Using the System System Reset In the unlikely event of the unit locking up pressing the Reset button will cause the unit to re boot I O Setup Press the FUNC button until I O Setup is displayed I O number Press the SEL button until the curser is on...

Страница 16: ... indicators for system faults The CPU LED indicates that the internal CPU microprocessor is in a fault condition The GEN LED indicates a general fault condition When either of these LEDs is on a system fault has occurred PWR SER A green PWR Power LED indicates that the internal power supplies are operating The SER Serial LED is on when the serial connection is in use Front Panel Indicators 11 ...

Страница 17: ...ergized When the LED is off a fault has occurred and Relay R1 is de energized R2 R3 and AUX LEDs are for future use Protocessor The Protocessor LEDs indicate the state of the Protocessor The ERR LED will go on solid 15 seconds after power up It will turn off after 5 seconds A steady red light will indicate there is a system error on the unit The RUN LED will start flashing 20 seconds after power i...

Страница 18: ...he Opt button to cycle through additional IP settings including Subnet Gateway and MAC ID 6 We can also change the IP settings by navigating the IP address displayed on the Head End display Changing the IP Settings using the System Manager Webpages 1 Make sure your static IP is set on your PC and you have internet connection going from your PC to the Protocessor Field Pop Enabled port on the back ...

Страница 19: ...b X C I Cl 192 168 100 225 2 On the Lencore Landing page click the System Settings options LENCORE Please login to begin Usemame comfort Password comfort Login Y Stem Setting Addressbook 3 login to the System Settings pages Default Username and Password comfort comfort Configuring The Time Settings 14 ...

Страница 20: ...Configuring The Time Settings 15 ...

Страница 21: ... C I Cl 192 168 100 225 2 On the Lencore Landing page click the System Settings options LENCORE Please login to begin Usemame comfort Password comfort Login Y Stem Setting Addressbook 3 login to the System Settings pages Default Username and Password comfort comfort Configuring The Fault Email Settings 16 ...

Страница 22: ...8 Open circuit on digital input 4 Gen 1 23 Open circuit on digital input 5 Gen 1 28 Open circuit on digital input 6 Gen 1 33 Open circuit on digital input 7 Gen 1 38 Open circuit on digital input 8 Gen 1 43 Open circuit on digital input 9 Gen 1 48 Open circuit on digital input 10 Gen 1 53 Open circuit on digital input 11 Gen 1 58 Open circuit on digital input 12 17 ...

Страница 23: ...efault IP 192 168 100 225 New Tab X C I Cl 192 168 100 225 2 On the Lencore Landing page click the System Settings options LENCORE Please login to begin Usemame comfort Password comfort Login Y Stem Setting Addressbook 3 login to the System Settings pages Default Username and Password comfort comfort 14 ...

Страница 24: ...Configuring The SMTP Settings 19 ...

Страница 25: ...e probe on your OHM meter Next insert the probes into your OHM meter Plug the RJ45 on the opposite end of your cable into your coupler Insert a speaker run Channel A B etc into the other end of your coupler If all is connected correctly you will see the following correct results on your OHM meter Higher is typically OK as that represents longer cables Values are approx based on 25 cable run from i...

Страница 26: ...on how to complete the testing Refer to the Operations System Manager and Configurator manuals for detailed information Testing should be performed monthly or more frequently if necessary 1 2 3 4 Test any output relays that are being used Using System Manager assure all OP s are on line Verify Faults in Unit trigger a fault in FACP Verify FACP Mute Masking functions correctly 21 ...

Страница 27: ... instruction on how to complete the activities Maintenance should be performed monthly or more frequently if necessary 1 Inspect and clean if necessary all air vent openings 2 Inspect and replace if necessary the AC power cord for exposed wires torn or worn insulation or a broken cord retaining clamp 3 Ensure that all cables and wires are properly seated in their respective connectors 22 ...

Страница 28: ... for the product to comply with the requirements in the Standard for Control and Communication Units for Mass Notification Systems UL2572 certain programming features or options must be limited to specific values or not used at all as indicated below Program feature or option Permitted in UL2572 Y N Possible settings Settings permitted in UL2572 23 ...

Страница 29: ... an open architecture software platform that controls and monitors the finished system It can be accessed from any desktop or wireless computer with an Internet browser The System Manager user interface can be used to Tune the sound masking system for volume contour equalization Create groups for masking zones paging zones and music zones Control volume and equalization for paging and music Run di...

Страница 30: ...ress that is different from the headends IP address other than 192 168 100 225 For example a good IP address for the computer is 192 168 100 200 Consult with an IT professional if you do not understand these instructions To configure the computer complete the following Turn the computer on allow the computer to boot completely plug in using the data cable from the computer to the headends TURN off...

Страница 31: ...perties select the option Use the following IP address and complete the following In the IP address section enter 192 168 100 200 Press the Tab key on the keyboard to jump to Subnet section leave this area set to 255 255 255 0 Press the Tab key on the keyboard to jump to the Gateway section The computer Gateway must match the Gateway assigned to the system if a specific gateway was entered Click O...

Страница 32: ... not include www or http 3 After you type in the correct address such as 192 168 100 225 press return and you will see the Lencore System Manager displayed in your Internet browser 4 You will be prompted with a box asking for a username and password see pg 6 Mac OS 27 Go to System Preferences Select Network On the left menu select Ethernet Select the drop down menu of configure IPv4 and select man...

Страница 33: ... browser as listed in the Compatibility section above The default Username and Password are both comfort case sensitive After entering the correct credentials press the Login button to enter the main system selection screen where you will be presented with five tabbed options to select from Devices Zone EQ and System 28 ...

Страница 34: ...on Revision Author A B 6 10 18 Initial Release M Cook 8 30 18 Added various notes per ETL M Cook C 9 18 18 Added various text for UL864 M Cook D 10 1 18 Added configuration settings T Smith E 7 23 20 Changed password M Cook F 11 17 22 added p24 S James ...

Страница 35: ...re com www lencore com The information contained herein is proprietary to Lencore Acoustics LLC and copyright protected No part of this manual can be copied used or distributed without prior authorization from Lencore Acoustics Corp Copyright 2022 ...