To check all speaker wires and speakers for their integrity unplug the 1st speaker wire from the i.Net OP
and connect an RJ45 to an 8 conductor CAT5 wire on one end and twist wire/pins 1, 2, 3,4 together
and 5, 6, 7, 8 together.
•
This will give you two leads plus & minus.
•
Attach the Positive lead to the positive probe and the Negative lead to the negative probe on your OHM
meter. Next, insert the probes into your OHM meter. Plug the RJ45 on the opposite end of your cable
into your coupler.
•
Insert a speaker run (Channel A, B, etc.) into the other end of your coupler.
•
If all is connected correctly, you will see the following correct results on your OHM meter. Higher is
typically OK as that represents longer cables.
*Values are approx. based on 25’ cable run from i.Net OP to speaker and from speaker to speaker
# of Speakers
1
2
3
4
5
6
7
8
OHMs-K
26
13
8.67
6.5
5.2
4.33
3.71
3.25