Figure 44. Installing intrusion switch
2
Slide the intrusion switch until it is firmly seated in the intrusion switch slot.
3
Connect the intrusion switch cable to the connector on the system board.
Next steps
1
Installing the internal PERC riser
2
Follow the procedure listed in
After working inside your system
.
Drives
Removing a drive blank
The procedure for removing 2.5-inch and 3.5-inch drive blanks is identical.
Prerequisites
1
Follow the safety guidelines listed in
2
If installed,
CAUTION:
To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION:
Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release button, and slide the drive blank out of the drive slot.
Installing and removing system components
91
Содержание E46S001
Страница 28: ...System information label Figure 17 PowerEdge R540 Service information 28 Dell EMC PowerEdge R540 overview ...
Страница 30: ...Figure 21 Rear drive installation 30 Dell EMC PowerEdge R540 overview ...
Страница 75: ...Figure 29 Inside the system without rear drive cage Installing and removing system components 75 ...