NOTE:
Ensure that the PHM is held parallel to the system board to prevent damaging the components.
2
Push the blue retention clips inward to allow the heat sink to drop into place.
3
Using the Torx #T30 screwdriver, tighten the screws on the heat sink in the order below:
a Partially tighten the first screw (approximately 3 turns).
b Tighten the second screw completely.
c Return to the first screw and tighten it completely.
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a
Loosen both the heat sink screws completely.
b
Lower the PHM on to the blue retention clips, following the procedure described in step 2.
c
Secure the PHM to the system board, following the replacement instructions listed in this step above. 4.
Figure 64. Installing the processor and heat sink module
Next steps
1
2
Follow the procedure listed in
After working inside your system
.
112
Installing and removing system components