Table 5. System health and system ID indicator codes
System health and system ID indicator code
Condition
Solid blue
Indicates that the system is turned on, system is healthy, and system
ID mode is not active. Press the system health and system ID button
to switch to system ID mode.
Blinking blue
Indicates that the system ID mode is active. Press the system health
and system ID button to switch to system health mode.
Solid amber
Indicates that the system is in fail-safe mode. If the problem persists,
see the Getting help section.
Blinking amber
Indicates that the system is experiencing a fault. Check the System
Event Log or the LCD panel, if available on the bezel, for specific error
messages.
For more information about error messages, see the
Event and Error
Message Reference Guide for 14th Generation Dell EMC PowerEdge
Servers
at
iDRAC Quick Sync 2 indicator codes
iDRAC Quick Sync 2 module (optional) is located on the front panel of your system.
Table 6. iDRAC Quick Sync 2 indicators and descriptions
iDRAC Quick Sync 2 indicator
code
Condition
Corrective action
Off (default state)
Indicates that the iDRAC Quick Sync 2
feature is turned off. Press the iDRAC Quick
Sync 2 button to turn on the iDRAC Quick
Sync 2 feature.
If the LED fails to turn on, reseat the cable and check.
If the problem persists, see the
section.
Solid white
Indicates that iDRAC Quick Sync 2 is ready
to communicate. Press the iDRAC Quick
Sync 2 button to turn off.
If the LED fails to turn off, restart the system. If the
problem persists, see the
section.
Blinks white rapidly
Indicates data transfer activity.
If the indicator continues to blink indefinitely, see the
section.
Blinks white slowly
Indicates that firmware update is in
progress.
If the indicator continues to blink indefinitely, see the
section.
Blinks white five times rapidly and
then turns off
Indicates that the iDRAC Quick Sync 2
feature is disabled.
Check if iDRAC Quick Sync 2 feature is configured to
be disabled by iDRAC. If the problem persists, see the
section. For more information, see
Integrated Dell Remote Access Controller User's
Guide
at
Dell
OpenManage Server Administrator User’s Guide
at
> OpenManage Server
Administrator.
Solid amber
Indicates that the system is in fail-safe
mode.
Restart the system. If the problem persists, see the
section.
14
Dell EMC PowerEdge R540 overview
Содержание E46S001
Страница 28: ...System information label Figure 17 PowerEdge R540 Service information 28 Dell EMC PowerEdge R540 overview ...
Страница 30: ...Figure 21 Rear drive installation 30 Dell EMC PowerEdge R540 overview ...
Страница 75: ...Figure 29 Inside the system without rear drive cage Installing and removing system components 75 ...