c
Update the BIOS and iDRAC versions.
d
Re-enable the Trusted Platform Module (TPM). For more information, see the
Upgrading the Trusted Platform Module
section.
5
Import your new or existing iDRAC Enterprise license.
For more information, see
Integrated Dell Remote Access Controller User's Guide
, at
Restoring the system using easy restore
The easy restore feature allows you to restore your service tag, license, UEFI configuration, and the system configuration data after
replacing the system board. All data is backed up in a backup flash device automatically. If BIOS detects a new system board, and the
service tag in the backup flash device, BIOS prompts the user to restore the backup information.
Below is a list of options available:
•
Restore the service tag, license, and diagnostics information, press
Y
•
Navigate to the Lifecycle Controller based restore options, press
N.
•
Restore data from a previously created
Hardware Server Profile
, press
F10
NOTE:
When the restore process is complete, BIOS prompts to restore the system configuration
data.
•
To restore the system configuration data, press
Y
•
To use the default configuration settings, press
N
NOTE:
After the restore process is complete, system reboots.
Manually update the Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using
System Setup
.
About this task
If you know the system service tag, use the
System Setup
menu to enter the service tag.
Steps
1
Power on the system.
2
To enter the
System Setup
, press
F2
.
3
Click
Service Tag Settings
.
4
Enter the service tag.
NOTE:
You can enter the service tag only when the Service Tag field is empty. Ensure that you enter the correct service
tag. Once the service tag is entered, it cannot be updated or changed.
5
Click
OK
.
Entering the system Service Tag by using System
Setup
If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.
1
Turn on the system.
2
Press F2 to enter System Setup.
3
Click
Service Tag Settings
.
4
Enter the Service Tag.
NOTE:
You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct Service
Tag. After the Service Tag is entered, it cannot be updated or changed.
5
Click
OK
.
174
Installing and removing system components