8.7.5 Printing Test Reports
In the Test Report Viewer, press the "Print" button to show the print dialogue. Select the printer
and press OK to print all the test reports currently in the viewer. Pressing Cancel will close the print
dialogue without printing.
8.7.6 Saving Test Reports
Test Reports that are displayed on the Test Report Generator screen must be saved before exiting
the ES601pc program, or they must be downloaded again the next time the program is run. The
Test Reports shown on the screen after downloading will remain active in the program until
ES601pc is exited. The reports will still be available if the Report Generator is exited and re-entered,
but the main program is not shut down. Be sure to save any records you wish to keep
b e fo re
deleting them from ES601
Plus
.
Saving to text
In the Test Report Viewer, test reports can be saved in both TXT (Text) and CSV (Comma
Separated Values) formats. To save test reports in text format, press Save To Text in the Test
Report Viewer. A directory browser will appear. Select the directory where the test reports should be
saved. A report for each individual test will now be saved in its own file with the following filename
format:
DeviceID.yyyy
_
mm
_
dd.hh
_
mm
_
ss.txt
Where DeviceID is the device ID (equipment control number or other ID), yyyy is the year, mm is
the month, dd is the day, hh is the hour, mm is the minute, and ss is the second in which the Test
Report was created.
Linked test reports can also be created. Test reports are linked by means of a common Parent ID,
such as might be the case when modules of a multi-parameter patient monitor (the "devices") all
have been tested using the same mainframe video monitor (the "parent"). In a linked report, the test
reports of the individual devices are combined into one report and saved as a text file. To create a
linked report, check the Create Linked Reports checkbox before viewing selected test reports. Now
any test reports having common Parent ID's will be linked and saved as files having filenames in the
following format:
ParentID.yyyy
_
mm
_
dd.hh
_
mm
_
ss.txt
where ParentID is the Parent ID, yyyy is the year, mm is the month, dd is the day, hh is the hour,
mm is the minute, and ss is the second in which the Test Report was created.
ES601pc Software/Chapter 8
#
Page 161
Содержание ES601 Plus
Страница 1: ...Operating Manual ES601Plus Inte rnatio nal Auto m ate d Ele c tric al Safe ty Analyze r ...
Страница 2: ......
Страница 4: ......
Страница 8: ...Page iv ...
Страница 19: ...ES601Plus OPERATING MANUAL Definitions Page xv ...
Страница 39: ...ES601Plus OPERATING MANUAL Overview Chapter 2 Page 20 ...
Страница 57: ...ES601Plus OPERATING MANUAL Setup Chapter 3 Page 38 ...
Страница 59: ...ES601Plus OPERATING MANUAL Fig ure 13 Connecting to a line powered DUT Connecting To ES601 Chapter 4 Page 40 ...
Страница 117: ...ES601Plus OPERATING MANUAL Manual Testing Chapter 5 Page 98 ...
Страница 151: ...ES601Plus OPERATING MANUAL Automated Testing Chapter 6 Page 132 ...
Страница 159: ...ES601Plus OPERATING MANUAL Computer Control Chapter 7 Page 140 ...
Страница 193: ...ES601Plus OPERATING MANUAL ES601pc Software Chapter 8 Page 174 ...
Страница 195: ...ES601Plus OPERATING MANUAL ES601pc Software Chapter 8 Page 176 ...
Страница 223: ...ES601Plus OPERATING MANUAL Appendix B Page 204 ...
Страница 227: ...ES601Plus OPERATING MANUAL Appendix C Page 208 ...
Страница 228: ...ES601Plus OPERATING MANUAL APPENDIX D Importing Equipment Records Appendix D Page 209 ...
Страница 229: ...ES601Plus OPERATING MANUAL Appendix D Page 210 ...