5-45
Y15 turns ON in Initial, Protection or Configuration state.
Y16 turns ON when in Run state.
Refer to “Chapter 4 BASIC OPERATION”, or “Chapter 6 TROUBLESHOOTING”, for details of the each
state.
Warning
The monitor outputs are not safety outputs. Do not use these to construct a safety system.
●
Solenoid outputs: Y17 and Y20
Y17 and Y20 are outputs for solenoid control that are used for a safety switch with a lock.
In the Run state, when the safety outputs are OFF and 1 or more safety inputs are OFF, the
solenoid outputs are turned ON. When all safety inputs are ON, the solenoid outputs are turned
OFF, although the start input is not activated.
Warning
Solenoid outputs are not safety outputs. Do not use these to construct a safety system.
Caution
Refer to "Chapter 2 PRODUCT SPECIFICATIONS" for specifications of each input and output.