Warning
Do not connect devices having input and output specifications that do not satisfy the
requirements of the SG-ONE.
Refer to the following for information on the requirements of connected devices.
Connected Control Device
Requirements
Emergency stop switch
Device equipped with a direct opening action mechanism conforming to
IEC/EN60947-5-5 or indicated in IEC/EN60947-5-1
Interlock switch,
limit switch
Device equipped with a direct opening action mechanism indicated in
IEC/EN60947-5-1
Safety switch with lock
Spring lock safety switch with solenoid
Mode select switch
Device conforming to regulations of the country where used and required
categories (for example, switch conforming to IEC/EN60947-1)
Enabling switch
Device conforming to IEC/EN60947-5-8 (or IEC/EN60947-5-1)
Solid state output device
Device conforming to regulations of the country where used (for example,
safety light curtain conforming to IEC/EN61496-1)
PNP output (See Note 1)
Non-contact interlock switch Device designed to work together with hinged, sliding, or lift-off guards and
barriers conforming to regulations of the country where used
Safety relay
Relay equipped with forced guide mechanism or conforming to EN50205
Contactor
(electromagnetic switch)
Contactor equipped with forced guide mechanism
Other control devices
Use start switches and other devices that conform to the regulations of the
country where used.
Muting sensor
Device conforming to IEC/EN60947-5-2 as shown below
-3 wire transmission (dark on) photoelectric switch which has a PNP open
collector output.
-3 wire (normal open) proximity switch which has a PNP open collector
output.
Muting lamp
Incandescent bulb indicator light conforming to IEC/EN60947-1 or
IEC/EN60947-5-1
Note 2: It is not possible to detect a disconnection of the muting lamp when
using an LED indicator light.
Make sure that the end-user thoroughly understands the contents of this user’s manual.
Note 1: Use the solid state output device that sends output signal of the waveforms shown below.
Otherwise the SG-ONE cannot process the input signal correctly.
Software version
1.20
1.30 or later
Applicable solid state
output device
Pulse output off cycle of 40ms or
more and an off time of 1ms or less.
Pulse output off time of 0.5ms or
less or same as version 1.20.
(Waveform of solid sate
output)
The device may not be usable even if the above specifications are satisfied. Be sure to
thoroughly confirm operations using the actual device.
Software version is described at the next of serial number on the product label.
S/N****-***** 1V130 ****
Software version 1.30
Serial number
Off cycle: 40ms or more
Off time:
1ms or less
Off time: 0.5ms or less
Содержание SG EASY One
Страница 1: ...Safety Control Unit INSTRUCTION MANUAL...
Страница 12: ...2 2 Dimensions 120 0 1 7 1 5 133 5 113 5 122 0 109 5 114 5 72 0 Locking hole Detail of locking hole...
Страница 34: ......
Страница 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Страница 71: ...5 29 Timing chart Logic 3...
Страница 74: ...5 32 Logic circuit Logic 4...
Страница 80: ...5 38 Timing chart Logic 4...
Страница 81: ...5 39...
Страница 103: ...5 61 Operation example Logic 7 Machine running Machine stop danger zone A Movable guard A is opened...