2-13
(3) Timer LED
Indication
Status
Descriptions
0
ON
No OFF-delay (safety outputs shut off immediately)
.1
ON
OFF-delay timer 0.1s
.5
ON
OFF-delay timer 0.5s
1
ON
OFF-delay timer 1s
2
ON
OFF-delay timer 2s
5
ON
OFF-delay timer 5s
15
ON
OFF-delay timer 15s
30
ON
OFF-delay timer 30s
Each LED
Blink
Selected timer value (Configuration state)
Random
ON/Blink
Initializing (Initial state)
Blank
OFF
Timer value is not selected or SG-ONE is in the Stop state
(4) Input LED
:
SAFE-IN (X0 … X15), START-IN (X16, X17)
Indication
Status
Descriptions
ON
Input ON
OFF
Input OFF, or SG-ONE is in the Stop or Configuration
state
X0 to X15
Blink
Input monitor error
ON
Input ON
X16, X17
OFF
Input OFF, or SG-ONE is in the Stop or Configuration
state
Indicators specification of input LEDs are different depending on the selected logic.
(5)
Output LED: SAFE-OUT (Y0 … Y3), SOLENOID-OUT (Y17, Y20)
Indication
Status
Descriptions
ON
Output ON
OFF
Output OFF, or SG-ONE is in the Stop or Configuration
state
Y0 to Y3
Blink
During OFF-delay timer operation
ON
Output ON
Y17, Y20
OFF
Output OFF, or SG-ONE is in the Stop or Configuration
state
Содержание SG EASY One
Страница 1: ...Safety Control Unit INSTRUCTION MANUAL...
Страница 12: ...2 2 Dimensions 120 0 1 7 1 5 133 5 113 5 122 0 109 5 114 5 72 0 Locking hole Detail of locking hole...
Страница 34: ......
Страница 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Страница 71: ...5 29 Timing chart Logic 3...
Страница 74: ...5 32 Logic circuit Logic 4...
Страница 80: ...5 38 Timing chart Logic 4...
Страница 81: ...5 39...
Страница 103: ...5 61 Operation example Logic 7 Machine running Machine stop danger zone A Movable guard A is opened...