6-2
5
ON OFF OFF Muting lamp error
(broken wire)
(For logic 4 only)
Broken wire of
muting lamp
wiring
Broken wire of
Muting lamp
Check functionality and
wiring of the muting
lamp.
Check the operation of
the muting lamp.
6
ON
ON
OFF Fault in power supply
or internal power
supply circuit
The voltage of
the power supply
to SG-ONE is
not within the
allowable range.
Check voltage of the
power supply to the
SG-ONE.
7
ON
ON
OFF Fault in power supply
or internal power
supply circuit
The voltage of
power supply to
SG-ONE is not
within the
allowable range.
Check voltage of power
supply to SG-ONE.
7
ON OFF OFF Internal
circuit
error
Internal failure of
the SG-ONE
Replace the SG-ONE.
9
ON
OFF OFF Noise filter error
Noise influences
to the SG-ONE
or input/output
line.
Check noise in the
surrounding
environment.
C
OFF ON OFF Changing to the
Configuration state
- -
The state of the input LEDs and monitoring output varies depending upon the logic selected.
Refer to “Chapter 4 BASIC OPERATIONS” and "Chapter 5 LOGIC" for details.
Содержание SG EASY One
Страница 1: ...Safety Control Unit INSTRUCTION MANUAL...
Страница 12: ...2 2 Dimensions 120 0 1 7 1 5 133 5 113 5 122 0 109 5 114 5 72 0 Locking hole Detail of locking hole...
Страница 34: ......
Страница 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Страница 71: ...5 29 Timing chart Logic 3...
Страница 74: ...5 32 Logic circuit Logic 4...
Страница 80: ...5 38 Timing chart Logic 4...
Страница 81: ...5 39...
Страница 103: ...5 61 Operation example Logic 7 Machine running Machine stop danger zone A Movable guard A is opened...