Specification of configuration switches
(1) Logic switch
The logic switch is an 8-digit DIP switch for use in logic configuration. When one of 8 digits is
selected, the corresponding logic in the SG-ONE is activated. See “Chapter 5 Logic” for further
information of each logic. The upper position of each digit is the ON state.
Multiple switches
must not be selected.
(2)
Timer switch
The timer switch is an 8-digit DIP switch for use in OFF-delay timer value configuration. When
one of 8 digits is selected, the delay time at shut-off operation is activated. The upper position of
each digit is ON state.
Multiple switches must not be selected.
Switch
(Indication)
Descriptions
0
1
No OFF-delay (safety outputs shut OFF immediately)
.1
2
OFF-delay timer 0.1s
.5
3
OFF-delay timer 0.5s
1
4
OFF-delay timer 1s
2
5
OFF-delay timer 2s
5
6
OFF-delay timer 5s
15
7
OFF-delay timer 15s
30
8
OFF-delay timer 30s
(3)
Enter button
The enter button is used to activate the configuration of logic and timer value. Error LED will
blink for 1 to 5 seconds after pressing the enter button. Releasing the button during blinking
activates the setting. The blinking LED becomes ON if the button is pressed for more than 5
seconds, and the setting becomes invalid even after the button is released.
Caution
For setting the swithes and enter button, use the configuration tool supplied with the SG-ONE.
(1) (2)
(1) Logic switch
(2) Timer switch
(3) Enter button
(3)
LOGIC No.
TIMER (S)
ENTER
0 .1 .5 1 2 5 15 30
1 2 3 4 5 6 7 8
Содержание SG EASY One
Страница 1: ...Safety Control Unit INSTRUCTION MANUAL...
Страница 12: ...2 2 Dimensions 120 0 1 7 1 5 133 5 113 5 122 0 109 5 114 5 72 0 Locking hole Detail of locking hole...
Страница 34: ......
Страница 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Страница 71: ...5 29 Timing chart Logic 3...
Страница 74: ...5 32 Logic circuit Logic 4...
Страница 80: ...5 38 Timing chart Logic 4...
Страница 81: ...5 39...
Страница 103: ...5 61 Operation example Logic 7 Machine running Machine stop danger zone A Movable guard A is opened...