5-71
Logic 8: Partial stop 2 logic for various machinery
Overview (Logic 8)
The logic described is for safety protective measures of equipment which has 2 separate
devices that are stopped by safety outputs independently, such as semiconductor
manufacturing machines, and food packaging machinery. When 2 devices can not be stopped
at the same time or it is not necessary, that 2 safety outputs can be controlled separately. This
logic enables the connection 5 dual channel direct opening inputs.
When in the state in which safety inputs 1, 2, and 3 correspond to safety outputs 1 and 2 can
receive the safety input signals (the contacts of the connected safety devices are ON), the
safety output 1 is turned ON upon input of the start input. When in the state in which the all of
the safety inputs 1 to 5 can receive safety input signals, safety outputs 1 and 2 are turned ON
upon input of the start input.
The safety outputs 1 and 2 are ON, if the input signal to safety inputs 1, 2, or 3 is turned OFF
(the contact of the safety device is OFF), safety outputs 1 and 2 are turned OFF after the preset
OFF-delay time.
If the safety input signal to safety inputs 4 or 5 corresponding to safety output 2 is turned OFF,
safety output 2 is turned OFF.
Note: Refer to "Logic circuit" for the details of safety inputs 1, 2, 3, 4, 5 and safety outputs 1, 2.
Содержание SG EASY One
Страница 1: ...Safety Control Unit INSTRUCTION MANUAL...
Страница 12: ...2 2 Dimensions 120 0 1 7 1 5 133 5 113 5 122 0 109 5 114 5 72 0 Locking hole Detail of locking hole...
Страница 34: ......
Страница 70: ...5 28 Using an DATALOGIC AUTOMATION light curtain SE series as S1 S2...
Страница 71: ...5 29 Timing chart Logic 3...
Страница 74: ...5 32 Logic circuit Logic 4...
Страница 80: ...5 38 Timing chart Logic 4...
Страница 81: ...5 39...
Страница 103: ...5 61 Operation example Logic 7 Machine running Machine stop danger zone A Movable guard A is opened...