3-2
●
Prevent SG-ONE from falling while moving or transporting the SG-ONE, otherwise damage or
malfunction of the SG-ONE may result.
●
Prevent metal fragments and pieces of wire from dropping inside the SG-ONE housing.
●
Install SG-ONE, so that there is adequate spacing from walls, heat generating bodies, and
peripherals, taking into consideration space requirements for maintenance and ventilation.
●
Install SG-ONE on 35mm DIN rails with BNL6 mounting clips (sold separately) on both sides of
SG-ONE.
●
Perform wiring to the connectors with proper cables or ferrules.
●
Ground FE terminal to assure electromagnetic compatibility (EMC)
●
Use common 0V DC, if different power supplies are used for SG-ONE and other devices (ex.
safety light curtains).
●
Install wiring for the inputs and outputs so that it is separated from power lines.