Figure 22. Local analog loopback in an electric E3 interface
7.8. Local Digital Loopback – LDL
Tests the external link and the two transmission directions. The figure below gives an example
of the test conditions.
Figure 23. Local digital loopback in electric E3 interface
7.9. Location of Straps in DM16E1-E3E Cards
In order to access the straps, remove the card from the aggregate slot:
••••
E1 – Grounding of the transmission coaxial cable (OUT).
••••
E2 – Grounding of the reception coaxial cable (IN).
••••
CONN position: grounds the coaxial cable shield.
••••
ISOL position: does not ground the coaxial cable shield.
Figure 24. Strap location
The DM16E1-E3Ei internal card uses the tributary 1 connectors. Thus, the function of the straps
mentioned above is carried out by the straps of tributary 1. See item 10.2 for more information.
7.10. Operation via Terminal
DM16E1 and DM4E1 can use either optic or electric aggregates. In both cases, configuration is the same.
For a reference on how to configure electric aggregate interfaces, consult chapter 6.7.
The configuration requirements for the internal electric E3 tributary are described below.