Changing Programmer Status ■ Disabling Programmers
- 70 -
Data I/O ■ 096-0466-001E
The programmer status
menu is shown in Figure
An optional method of
changing programmer
and socket status is with
the Programmer
Interface window.
(Setup window > Sys-
tem > Programmers)
See the on-screen Help
for more information.
Changing Programmer Status
PSV5000 may automatically disable a programmer for various reasons (for
example, if there are repeated continuity errors or vacuum issues). The op-
erator may also choose to disable a programmer, or otherwise change the
status of a programmer.
Disabling Programmers
If programmers are not performing and the error cannot be cleared, disable
those programmers and continue to use the other sites to process devices.
To disable a programmer:
1.
At the
Run
window, click
Pause
.
2.
Right-click on the target programmer and select All => DISABLED. All
sockets on this programmer change to black and are effectively disabled.
To disable a single socket, right-click the socket and select
=> DISABLED.
The socket changes to black and is disabled.
To resume a job click
Run
. When the job finishes, click
Clear
or manually
remove any devices from the disabled programmer sockets.
Clearing a Disabled Status
If a programmer is disabled (the PNP head skips it) it may be re-enabled if
there are no devices in it as follows:
1.
At the
Run
window, click
Pause.
2.
Right-click on the target programmer and select All => EMPTY. This
DOES NOT REMOVE DEVICES FROM THE SOCKETS, only changes the
status.
To re-enable a single, empty socket, right-click the socket
and select
=> EMPTY.
This DOES NOT REMOVE DEVICES FROM THE SOCKET, only changes
the status.
All sockets on this programmer change to grey and are re-enabled UNLESS
THEY WERE NOT EMPTY.
3.
To resume a job click Run.