■ List of Steps to Start a Job
≡
Socket Adapters and Actuator Plates
PSV5000 Operator’s Manual
- 37 -
Figure 36:
One clamp open with a Socket Adapter installed. The cham-
fered corners are to the left (arrows). There is an alignment hole in each
corner (two are covered by the label in this view.)
3.
Place the adapter to match the guide pin at each corner with the holes in
the adapter.
4.
(Optional) Place a second adapter at this clamp.
5.
Close the clamp. Make sure the latch snaps in place.
Removal is the reverse procedure. Lift gently by the socket.
Adjusting the Actuator Plates on LumenX Programmers
To adjust the Actuator Plates (both types, standard and HIC):
R
EQUIREMENTS
Head is parked.
Actuator for the programmer is in the UP position (sockets closed).
The nearest safety door is open.
1.
With a 2 mm hex key, loosen both screws for one actuator-sliding-bar
and slide it to align with the socket so that it only contacts the black part
of the socket body. On HIC Adapters, the bars cover the socket rollers.
2.
Tighten one screw for that bar, recheck alignment and tighten 2
nd
screw.
3.
Perform these steps for the second bar on this Actuator Plate.
4.
Test bar placement; with machine air off, manually press the actuator
down to contact the socket body. Ensure it opens the socket correctly.
Readjust the bar if necessary.
Adjust other Actuator Plates similarly as needed.