Running a Job on PSV5000 ■ List of Steps to Start a Job
- 38 -
Data I/O ■ 096-0466-001E
4>>
Identifying the Correct Probes
Different-sized devices may require a different-sized probe tip.
For the
most-reliable performance, use the largest nozzle/rubber cup outer
diameter (O.D.) possible for the target device
so as to create optimal
vacuum suction and ‘blow
-
off’ air when picking and placing devices
.
NOTE: For tip sizes not listed, refer to the original manual that came
with your PSV5000. The older tips can be used with the new holders.
Pictured Right:
Basic components of a probe assembly
on a PSV5000 pick-and-place (PnP) head.
Figure 37:
Probe Assembly.
To identify the correct tip assembly for your application:
1.
First select the largest
Nozzle
for your device, based on outer diameter.
The following table lists available nozzles and part numbers.
Tip OD
(mm)
Part
Number
Probe Tips (No Nozzle)
1.3
646-0167-001
NOZZLE,PROBE TIP,1.3MM x 0.9MM CUP,HITACHI HV03,PSV
Tip OD
(mm)
Part
Number
Nozzles for 1.9mm Square Holder
1.75
288-0014-001
VACUUM,CUP,1.75MM OD,FOR 1.9MM TIP,PSV
2.25
288-0013-001
VACUUM,CUP,2.25MM OD,FOR 1.9MM TIP,PSV
3.05
288-0040-130
VACUUM,CUP,3.05MM OD,FOR 1.9MM TIP,PSV